COMPLIMENTARY 2D OPTIONS
-
F-K Filter
-
Zero Phase Deconvolution
-
F-X Deconvolution
-
Radon Transform (Demultiple or Noise Attenuation)
-
Pre-stack Migration
STANDARD PROCESSING SEQUENCE
-
Demultiplex / Reformat
-
Coordinate Geometry Application
-
Spherical Divergence Correction
-
Automatic and Manual Trace Editing
-
Instrument and Geophone signature Dephasing
-
Minimum Phase Vibroseis Correction (if applicable)
-
F-K Filter (Optional)
-
5 Component Surface Consistent Amplitude Scaling
-
5 Component Surface Consistent Deconvolution (Frequency or Time Domain)
-
Ground Roll Equalization
-
Zero Phase Frequency Deconvolution
-
5 Component Surface Consistent Amplitude Scaling
-
Refraction Analysis and Statics Application on Every Shot (GLI or GRM)
-
Preliminary Velocity Analysis
-
1st Pass Surface Consistent Residual Static Correction
-
Final Velocity Analysis
-
2nd Pass Surface Consistent Residual Static Correction
-
Normal Moveout Correction
-
Front End Mute
-
Cross Correlation Statics Correction (Trim Statics)
-
Stack
-
Zero Phase Deconvolution
-
F-X Deconvolution
-
F-X-Y, FD, FK or Kirchhoff Migration
-
Frequency or Time Domain Bandpass Filter
-
Final Trace Equalization Scaling
-
Archive Final Stacks and CMP Gathers to choice of media